Coil Condensers are used for condensation of vapours and cooling of liquids. Condensers are made by fusing number of parallel coils in a glass shell. Coils are made in different diameters using tubes of different bores.
The average co-efficient of heat transfer in coil condenser is considered as :-
Condensation 200 – 270 Kcal/m2, hr, °C appx.
Cooling 100 – 150 Kcal/m2, hr, °C appx.

| Cat. Ref. | DN | d/DN1 | L | L1 | Type | Actual H.T.A. m2 | Cross Area Cm2 | Free Coolant Rate kg/hr. | Max. Jacket Cap. Litre |
| HE3/3.5* | 80 | 16 | 600 | 75 | A | 0.35 | 5 | 1300 | 2 |
| HE4/5* | 100 | 19 | 600 | 75 | A | 0.50 | 30 | 2400 | 4 |
| HE4/6 | 100 | 19 | 750 | 100 | A | 0.60 | 30 | 2400 | 6 |
| HE6/10 | 150 | 25 | 600 | 100 | B | 1.00 | 52 | 2600 | 9 |
| HE6/15* | 150 | 25 | 850 | 100 | B | 1.50 | 52 | 2600 | 11 |
| HE9/25* | 225 | 25 | 800 | 110 | B | 2.50 | 125 | 3300 | 18 |
| HE12/25 | 300 | 25 | 600 | 125 | B | 2.50 | 175 | 5700 | 25 |
| HE12/40* | 300 | 25 | 900 | 125 | B | 4.00 | 175 | 5700 | 35 |
| HE16/40 | 400 | 25 | 600 | 125 | B | 4.00 | 450 | 6200 | 60 |
| HE16/50 | 400 | 25 | 700 | 125 | B | 5.00 | 450 | 6200 | 70 |
| HE18/60 | 450 | 40 | 750 | 150 | C | 6.00 | 820 | 4800 | 100 |
| HE18/80 | 450 | 40 | 900 | 150 | C | 8.00 | 820 | 6200 | 110 |
| HE24/120 | 600 | 50 | 1250 | 300 | C | 12.00 | 1520 | 6200 | 265 |